CNOTE

Modularity as a model

30 years of experience

About CNote

Whether it’s a next-generation data center project, an extension of an existing infrastructure, a need for back-up, edge-computing or blockchain, we will always be able to offer and design a scalable solution for your project that will grow with you.

Energy saving and space optimization

Reducing dependence on energy for cooling as much as possible represents a saving of more than 50% on your electricity bill. CNote racks allow for space optimization thanks to the possibility of concentrating servers, one against the other, and thus considerably reducing infrastructure requirements, such as racks, rooms and buildings. This space saving is also possible thanks to the limitation of the need for air conditioning equipment, technical floor, heavy fire extension systems, etc...

ITCOOLANT

ITCoolant is a new technology heat transfer fluid. It is recyclable, non-toxic, with a very long life span (15 years when used as prescribed). It has a low viscosity and a cooling capacity 1500 times higher than air (conventional cooling systems). Its technical characteristics guarantee the composition and stability of connections, cables and components of equipment and servers. Increases server life by 30%, reduces system failures by 65%, protects against dust, vibration and oxidation.

Energy recycling

Chilled water loop, air cooler, adiabatic tower, wind generator, thermalism, connection to a collective domestic water network, agricultural greenhouses, methane recovery plants, heated swimming pools.

Maintenance and unified supervision

Integrated DCIM, customized monitoring.
Supervision of all elements with a unified dashboard tailored to your needs.

Why use CNote?

// Whether it’s a backup project, an addition to an existing infrastructure, or the complete creation of a state-of-the-art data center, there will always be a CNote rack to suit your needs. The CNote 12 U, CNote 25 U and CNote 50 U are adaptable to all projects, from the smallest to the largest.

Cooling system
economic

Equipment life in single-phase immersion cooling, the fluid remains in its liquid phase. The electronic components are directly immersed in a dielectric liquid in a tight but easily accessible enclosure where the heat from the electronic components warms the whole assembly. Pumps are often used to circulate the heated fluid to a heat exchanger, where it is cooled and returned to the chamber.

Easy access to PDUs

The PDUs are easily accessible from the front of the rack. This allows for quick interventions in terms of connecting/ disconnecting equipment or maintenance on PDUs.

Emergency system

An emergency stop system is implemented in order to prevent a problem from occurring.

Sustainability

The service life of immersed equipment can be increased by 20%, as the components are no longer subject to the hazards of high temperature variations. Their operating temperature being constant, the equipment is no longer subject to the aggressions of dust, bacteria, thermal shocks and others...

Fitting out of premises

Existing premises can be used as data centers without the heavy investment in land that is required for traditional data centers today.

Water reuse

Limiting your energy needs is an important factor. Reusing the energy produced through the heated water is another. Indeed, multiple uses are possible with this water. If no use is possible, a closed circuit will be implemented and will reduce the necessary water consumption to zero liters.

Nullam urna scelerisque

The companies we work with

Tristique in quisque pulvinar molestie. Ut malesuada pulvinar est phasellus suspendisse augue eu.

Tristique in quisque pulvinar molestie. Ut malesuada pulvinar est phasellus suspendisse augue eu.

Discover all our models

// Whether it’s a next-generation data center project, an extension of an existing infrastructure, a need for back-up, edge-computing or blockchain, we can always offer and design a scalable solution for your project that will grow with you.

CNOTE - MODELS

Methodology, how does it work?

// In this period where it becomes essential to calibrate its projects, we take the commitment to offer accommodation that will scrupulously adapt to your expectations.

Les commentaires de nos clients

Technologie Dive IT

DiveIT, listening to you

// Do not hesitate to contact us

France

81, rue du traité de Rome 84911 AVIGNON Cedex 9
+33 (0)623501461
commercial@diveit.fr

Overseas

20, place du général de Gaulle, 97460 Saint Paul
+262 (0)692706867
commercial@diveit.fr

Spain

Osi 52-54, 08034 Barcelona
+34 (0)722654834 commercial@diveit.fr

Latin America

Oficina Comercial Basilio Pereira de la Luz, 1080 Montevideo - Uruguay
+589 26285072
commercial@diveit.fr

La modularité comme modèle.

Qu’il s’agisse d’un projet de centre de traitement de données de nouvelle génération, de l’extension d’une infrastructure existante, d’un besoin de back-up, d’edge-computing ou de blockchain, nous pourrons toujours vous offrir et concevoir une solution évolutive adaptée à votre projet qui grandira en même temps que vous.


Modèles

CNOTE-12

CNOTE-25

CNOTE-50

CNOTE-50 DUO
Nombre de baies1112
Nombre de U utiles (Immergés + secs)12+125+250+42*25+4
Nombre d'unités de refroidissement (UDR)111Nombre de 1
Capacité de refroidissement20 kW50 kW100 kW50 kW
Spécifications électriques (options)380/415 Vac 50/60 Hz 32 Amps, 63 Amps and 125 Amps
Consommation électrique1000 W1250 W2200 W1250 W
PUE estimé~ 1.05~ 1.03~ 1.02~ 1.03
RedondanceDeux pompes asservies
Dimensions des baies (L/h/l)134x140x91 cm134x140x91 cm275x140x91 cm268x140x91 cm
Dimensions des UDR (Uh/I)60x140x91 cm60x140x91 cm75x140x91 cm60x140x91 cm
Charge au sol575 kg/m2595 kg/m2645 kg/m2700 kg/m2
Caractéristiques de l'eauTempérature d'entrée de 5 à 32’C / 41 to 89°F. Eau réfrigérée recommandée au-delà 25 ’C / 7Tf
Options finales de traitement de la chaleur produiteBoucle d'eau réfrigérée, aéro-réfrigérant, tour adiabatique, aérogénérateur, thermalisme, raccordement à un réseau d'eau domestique collectif, serres agricoles, usines de récupération de méthane, piscines chauffées
DCIM (Supervision)DCIM intégré DiveIT control
ProtocolesSNMP, Modbus...
AlarmesConfigurables : emails / SNMP traps / SMS.
Monitoring environnementalTempérature de l'eau et du fluide, pression, état des pompes, niveau du fluide...

Modularity as a model.

Whether it’s a next-generation data center project, an extension of an existing infrastructure, a need for back-up, edge-computing or blockchain, we will always be able to offer and design a scalable solution for your project that will grow with you.


Models

CNOTE-12

CNOTE-25

CNOTE-50

CNOTE-50 DUO
Numbers of racks1112
Useful U (Immerged + dry)12+125+250+42*25+4
Number of cooling units (UDR)1111
Cooling capacity20 kW50 kW100 kW50 kW
Power requirements380/415 Vac 50/60 Hz 32 Amps, 63 Amps and 125 Amps
Power consumption1000 W1250 W2200 W1250 W
PUE (estimated)~ 1.05~ 1.03~ 1.02~ 1.03
RedundancyTwo liquids pumps
Rack dimension (WxHxD)134x140x91 cm134x140x91 cm275x140x91 cm268x140x91 cm
Cooling Unit (UDR) dimensions60x140x91 cm60x140x91 cm75x140x91 cm60x140x91 cm
Floor loading575 kg/m2595 kg/m2645 kg/m2700 kg/m2
Water supplied outlet estimatedWater inlet temperature 5 to 32°C / 41 to 89°F. Recommended water inlet temperature above 25°C / 77°F
Final heat rejections optionsWater-loop, aero-coolers, adiabatic tower, thermalism, connection to the domestic network
DCIM Integrated DCIM
ProtocolsOPC
AlarmsConfigurable : SNMP traps
Environmental monitoringWater and ITCoolant temperature, pressure, pumps level, fluid level and flow